GEVIBench › All sensors › ElectricPk
ElectricPk
Early voltage indicator using a cpGFP inserted into a voltage-sensing domain.
- Category: VSD-cpGFP GEVI
- Published: 2012-09-06 — PLoS ONE 2012
- Response polarity: negative-going (fluorescence decreases on depolarization)
- Spectrum: excitation peak 489 nm, emission peak 511 nm (ElectricPk)
- Plasmid: Addgene #40314
- Tags: cpEGFP, Fast
Headline values (as shown in the GEVIBench table)
| Metric | Value | Definition |
|---|---|---|
| Brightness (B/B_EGFP) | 0.32× EGFP | Molecular brightness relative to EGFP (extinction coefficient × quantum yield, or a measured ratio). Sensors not measured against EGFP directly are placed through a chain of pairwise brightness comparisons, combined by geometric mean. |
| Kinetics τ_on / τ_off (ms) | 2.2 / 36 ms | Activation / decay time constants in ms (amplitude-weighted mean τ for multi-exponential fits). The value shown averages the measurements made at physiological temperature (≥33 °C); if there are none, it is the measurement closest to 33 °C. |
| ΔF/F per 100 mV | -1.2% | Steady-state fluorescence change for a 100 mV depolarization step (−70 → +30 mV); the sign gives the polarity. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting. |
| ΔF/F per mV | 0.02% (estimated from the F–V curve) | Subthreshold sensitivity: fluorescence change per mV near rest (−90 to −50 mV). Where no value is reported directly, it is estimated from the F–V curve. |
| ΔF/F per AP | 0.7% | Fluorescence change per single action potential in neurons. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting. |
| AP width (FWHM, ms) | 4.4 ms | Full width at half maximum of the optical spike waveform. |
| Photostability t75% @ 100 mW/mm² | — | Time for fluorescence to fall to 75% of its initial value under one-photon illumination, linearly dose-scaled to 100 mW/mm² (t50% is used where the 75% crossing falls inside a fast initial transient). Two-photon curves are not dose-scaled and are excluded. |
| Papers using it (N_used) | 1 | Number of published research papers, tracked by GEVIBench, that used the sensor for an experiment (a popularity / track-record measure). |
Measurements and sources
Kinetics
- τ_on 2.24 ms, τ_off 35.6 ms at 35-37°C — Barnett 2012, Fig. 5A
ΔF/F per 100 mV
- -1.2% (peak), 1P — Barnett 2012, Fig. 4A
ΔF/F per action potential
- 0.7%, 1P — Barnett 2012, Fig. 7C
AP width (FWHM)
- 4.4 ms at 2000 Hz sampling, Mouse, hippocampal neurons, in vitro, 1P, 35-37°C — Barnett 2012, Fig. 7B
Brightness comparisons
- 0.32× the brightness of EGFP — doi:estimated from cpEGFP (GCaMP3) EC×QY vs EGFP
Fluorescence–voltage (F–V) curve
ΔF/F (%) at each membrane potential, normalized to 0 at −70 mV: -150 mV: 1.4%; -120 mV: 1%; -100 mV: 0.6%; -70 mV: 0%; -50 mV: -0.4%; 0 mV: -1%; 30 mV: -1.4% — Barnett 2012, Fig. 6B
Research papers using ElectricPk (1)
- A Fluorescent, Genetically-Encoded Voltage Probe Capable of Resolving Action Potentials — Barnett L, Platisa J, Popovic M, Pieribone VA, Hughes T, PLoS ONE 2012 (HEK293 cells, mouse hippocampal neurons, in vitro)
Data and citation
- llms.txt — summary for language models
- llms-full.txt — every sensor in full (Markdown)
- gevis.json — all values and measurements with sources (JSON)
- gevis.csv — one row per sensor (CSV)
Cite GEVIBench as: Adam E. Cohen and Daozheng Gong (2026). Voltage imaging: A practical guide. Neuron. https://doi.org/10.1016/j.neuron.2026.08.002
Generated from the GEVIBench database on 2026-10-12.