GEVIBench › All sensors › Mermaid

Mermaid

FRET-based GEVI using a VSD paired with coral-derived fluorescent proteins for ratiometric voltage.

Headline values (as shown in the GEVIBench table)

MetricValueDefinition
Brightness (B/B_EGFP)1.29× EGFPMolecular brightness relative to EGFP (extinction coefficient × quantum yield, or a measured ratio). Sensors not measured against EGFP directly are placed through a chain of pairwise brightness comparisons, combined by geometric mean.
Kinetics τ_on / τ_off (ms)10 / 19 msActivation / decay time constants in ms (amplitude-weighted mean τ for multi-exponential fits). The value shown averages the measurements made at physiological temperature (≥33 °C); if there are none, it is the measurement closest to 33 °C.
ΔF/F per 100 mV+40% (median of 2 measurements: +26.4%)Steady-state fluorescence change for a 100 mV depolarization step (−70 → +30 mV); the sign gives the polarity. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting.
ΔF/F per mV0.25% (estimated from the F–V curve)Subthreshold sensitivity: fluorescence change per mV near rest (−90 to −50 mV). Where no value is reported directly, it is estimated from the F–V curve.
ΔF/F per AP1.6%Fluorescence change per single action potential in neurons. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting.
AP width (FWHM, ms)—Full width at half maximum of the optical spike waveform.
Photostability t75% @ 100 mW/mm²4.1 sTime for fluorescence to fall to 75% of its initial value under one-photon illumination, linearly dose-scaled to 100 mW/mm² (t50% is used where the 75% crossing falls inside a fast initial transient). Two-photon curves are not dose-scaled and are excluded.
Papers using it (N_used)9Number of published research papers, tracked by GEVIBench, that used the sensor for an experiment (a popularity / track-record measure).

Measurements and sources

Kinetics

ΔF/F per 100 mV

ΔF/F per action potential

Brightness comparisons

Photobleaching

Fluorescence–voltage (F–V) curve

ΔF/F (%) at each membrane potential, normalized to 0 at −70 mV: -120 mV: -5%; -100 mV: -5%; -80 mV: -3%; -70 mV: 0%; -60 mV: 2%; -40 mV: 16%; -20 mV: 26%; 0 mV: 33%; 20 mV: 36%; 40 mV: 37% — Tsutsui 2008, Fig. 1e

Research papers using Mermaid (9)

Data and citation

Cite GEVIBench as: Adam E. Cohen and Daozheng Gong (2026). Voltage imaging: A practical guide. Neuron. https://doi.org/10.1016/j.neuron.2026.08.002

Generated from the GEVIBench database on 2026-10-12.