GEVIBench › All sensors › Positron2
Positron2
Positive-going Ace2N-HaloTag variant optimized for stronger spike and subthreshold responses in cultured neurons.
- Category: Chemigenetic GEVI
- Published: 2022-11-10 — Janelia Figshare 2022
- Derived from: Positron; also related to pAce
- Response polarity: positive-going (fluorescence increases on depolarization)
- Spectrum: excitation peak 534 nm, emission peak 554 nm (Positron2 (JF525))
- Plasmid: Addgene #239079
- Tags: Ace opsin, HaloTag, Positive-going, JF525
Headline values (as shown in the GEVIBench table)
| Metric | Value | Definition |
|---|---|---|
| Brightness (B/B_EGFP) | — | Molecular brightness relative to EGFP (extinction coefficient × quantum yield, or a measured ratio). Sensors not measured against EGFP directly are placed through a chain of pairwise brightness comparisons, combined by geometric mean. |
| Kinetics τ_on / τ_off (ms) | — | Activation / decay time constants in ms (amplitude-weighted mean τ for multi-exponential fits). The value shown averages the measurements made at physiological temperature (≥33 °C); if there are none, it is the measurement closest to 33 °C. |
| ΔF/F per 100 mV | +37% | Steady-state fluorescence change for a 100 mV depolarization step (−70 → +30 mV); the sign gives the polarity. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting. |
| ΔF/F per mV | 0.38% (estimated from the F–V curve) | Subthreshold sensitivity: fluorescence change per mV near rest (−90 to −50 mV). Where no value is reported directly, it is estimated from the F–V curve. |
| ΔF/F per AP | 15% | Fluorescence change per single action potential in neurons. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting. |
| AP width (FWHM, ms) | — | Full width at half maximum of the optical spike waveform. |
| Photostability t75% @ 100 mW/mm² | — | Time for fluorescence to fall to 75% of its initial value under one-photon illumination, linearly dose-scaled to 100 mW/mm² (t50% is used where the 75% crossing falls inside a fast initial transient). Two-photon curves are not dose-scaled and are excluded. |
| Papers using it (N_used) | 1 | Number of published research papers, tracked by GEVIBench, that used the sensor for an experiment (a popularity / track-record measure). |
Measurements and sources
ΔF/F per 100 mV
- +37%, 1P, dye JF525 — Hasseman 2022, Fig. 1
ΔF/F per action potential
- 15%, 1P, dye JF525 — Hasseman 2022, Fig. 2
Fluorescence–voltage (F–V) curve
ΔF/F (%) at each membrane potential, normalized to 0 at −70 mV: -110 mV: -12%; -90 mV: -7%; -70 mV: 0%; -50 mV: 8%; -30 mV: 16%; -10 mV: 24%; 10 mV: 32%; 30 mV: 37%; 50 mV: 41% — Hasseman 2022, Fig. 1
Research papers using Positron2 (1)
- Optimization of genetically encoded voltage and calcium indicators for in vivo imaging — Hasseman J, Abdelfattah AS, Arthur B, et al., Janelia Figshare 2022 (Rat, cortical/hippocampal neurons, in vitro)
Data and citation
- llms.txt — summary for language models
- llms-full.txt — every sensor in full (Markdown)
- gevis.json — all values and measurements with sources (JSON)
- gevis.csv — one row per sensor (CSV)
Cite GEVIBench as: Adam E. Cohen and Daozheng Gong (2026). Voltage imaging: A practical guide. Neuron. https://doi.org/10.1016/j.neuron.2026.08.002
Generated from the GEVIBench database on 2026-10-12.