GEVIBench › All sensors › ASAP4e
ASAP4e
Speed-optimized ASAP4 variant with fast kinetics and a large fluorescence increase per action potential.
- Category: VSD-cpGFP GEVI
- Published: 2023-07-06 — Nature Methods 2023
- Derived from: ASAP3
- Response polarity: positive-going (fluorescence increases on depolarization)
- Spectrum: excitation peak 375 nm, emission peak 524 nm (ASAP4e)
- Two-photon compatible: yes
- Plasmid: Addgene #201031
- Tags: cpGFP, Positive-going, Two-photon
Headline values (as shown in the GEVIBench table)
| Metric | Value | Definition |
|---|---|---|
| Brightness (B/B_EGFP) | 0.17× EGFP | Molecular brightness relative to EGFP (extinction coefficient × quantum yield, or a measured ratio). Sensors not measured against EGFP directly are placed through a chain of pairwise brightness comparisons, combined by geometric mean. |
| Kinetics τ_on / τ_off (ms) | 6.3 / 5.7 ms | Activation / decay time constants in ms (amplitude-weighted mean τ for multi-exponential fits). The value shown averages the measurements made at physiological temperature (≥33 °C); if there are none, it is the measurement closest to 33 °C. |
| ΔF/F per 100 mV | +210% (median of 3 measurements: +211%) | Steady-state fluorescence change for a 100 mV depolarization step (−70 → +30 mV); the sign gives the polarity. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting. |
| ΔF/F per mV | 1.1% | Subthreshold sensitivity: fluorescence change per mV near rest (−90 to −50 mV). Where no value is reported directly, it is estimated from the F–V curve. |
| ΔF/F per AP | 38% (median of 5 measurements: 33%) | Fluorescence change per single action potential in neurons. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting. |
| AP width (FWHM, ms) | 5 ms | Full width at half maximum of the optical spike waveform. |
| Photostability t75% @ 100 mW/mm² | — | Time for fluorescence to fall to 75% of its initial value under one-photon illumination, linearly dose-scaled to 100 mW/mm² (t50% is used where the 75% crossing falls inside a fast initial transient). Two-photon curves are not dose-scaled and are excluded. |
| Papers using it (N_used) | 6 | Number of published research papers, tracked by GEVIBench, that used the sensor for an experiment (a popularity / track-record measure). |
Measurements and sources
Kinetics
- τ_on 18.29 ms, τ_off 15.6 ms at 22°C — Evans 2023, Table S1
- τ_on 4.55 ms, τ_off 4.71 ms at 37°C — Evans 2023, Table S1
- τ_on 8.14 ms, τ_off 6.7 ms at 33°C — McDonald 2026, Table S1.4
ΔF/F per 100 mV
- +210%, 1P — Evans 2023, Table 1
- +148%, 2P — McDonald 2026, Fig. 1F
- +212%, 1P — Lee 2024, Table S1
ΔF/F per mV (subthreshold)
- 1.12%/mV, 2P (Cross-measured in the FORCE1s paper (McDonald et al. 2026). Subthreshold steady-state response to a 30-mV depolarization from −70 → −40 mV = 33.6 ± 6.4% (n = 5, whole-cell voltage clamp + 2P imaging at 33 °C, HEK293A; main text and Fig. 1E/Fig. S1.2C). Expressed as a slope: 33.6% / 30 mV ≈ 1.12 %/mV (cf. FORCE1s 87.4% → 2.91 %/mV, JEDI-2P 25.9% → 0.86 %/mV over the same step).) — McDonald 2026, Fig. 1E
ΔF/F per action potential
- 38%, 1P — Evans 2023, Table 1
- 23%, 1P — Evans 2023, Ext. Fig. 5a
- 41%, 1P — Evans 2023, Ext. Fig. 5c
- 33%, 1P — Lee 2024, Table S1
- 32%, 1P — Lee 2024, Table S4
AP width (FWHM)
- 5.8 ms at 400 Hz sampling, Mouse barrel cortex L2/3 pyramidal neurons, in vivo, whisker stimulation (ASAP4e-Kv), 2P, 37°C — Lee 2024, Fig. 3d
- 4.2 ms at 721 Hz sampling, HEK293A cells, whole-cell voltage clamp, in vitro (2-ms FWHM command AP waveform), 2P, 33°C — McDonald 2026, Fig. 1K
Brightness comparisons
- 0.362× the brightness of ASAP3 — Evans 2023, Ext. Fig. 3d
- 0.5× the brightness of FORCE1s — McDonald 2026, Fig. 1C
- 0.6666666666666666× the brightness of ASAP5 — Lee 2024, Table S4
- 1× the brightness of ASAP6c — Lee 2024, Table S4
- 0.03571428571428571× the brightness of pAce — Lee 2024, Table S4
- 0.2857142857142857× the brightness of Positron — Lee 2024, Table S4
Photobleaching
- t75% = 104 s at 100 mW at sample plane (2P, 940 nm), 2P — McDonald 2026, Fig. S1.2B
- curve only (did not reach 75% within the measured window) at 100 mW/mm², 1P — Evans 2023, Fig. 2b
- t75% = 141 s at 960 mW/mm² (2P galvanometric scanning, 5 min), 2P — Evans 2023, Ext. Fig. 4c
Fluorescence–voltage (F–V) curve
ΔF/F (%) at each membrane potential, normalized to 0 at −70 mV: -120 mV: -13%; -100 mV: -9%; -80 mV: -3%; -70 mV: 0%; -60 mV: 6%; -40 mV: 22%; -20 mV: 55%; 0 mV: 98%; 30 mV: 210%; 50 mV: 300%; 70 mV: 360%; 90 mV: 410%; 120 mV: 460% — Evans 2023, Fig. 1B
Research papers using ASAP4e (6)
- A positively tuned voltage indicator for extended electrical recordings in the brain — Evans SW, Shi DQ, Chavarha M, et al., Nature Methods 2023 (HEK293A cells (voltage clamp), mouse hippocampus and cortex, in vivo (origin paper introducing ASAP4e))
- Improving positively tuned voltage indicators for faster kinetics and higher contrast — Lee S, Zhang G, Hao YA, et al., bioRxiv 2024 (HEK293A cells, voltage clamp and AP-waveform characterization of ASAP4e)
- A versatile, positive-going voltage indicator that enables accessible two-photon recordings in vivo — McDonald AJ, Land MA, Yang S, et al., bioRxiv 2026 (HEK293A cells, ASAP4e benchmarked under 2P excitation against FORCE1s (kinetics, F-V, brightness, spike waveforms))
- Voltage imaging reveals hippocampal inhibitory dynamics shaping pyramidal memory-encoding sequences — Taxidis J, et al., Nature Neuroscience 2025 (Mouse, hippocampus CA1, PV and SST interneurons, in vivo)
- Imaging sensory transmission and neuronal plasticity in primary sensory neurons with a positively tuned voltage indicator — Zhang Y, et al., Nature Communications 2025 (Mouse, dorsal root ganglia neurons, in vivo)
- High-speed neural imaging with multiplexed miniaturized two-photon microscopy — Zhang Z, Liu SJ, Mattison B, Muir J, Spurr N, Kim CK, Yang W, Cell Reports Methods 2025 (Mouse, primary visual cortex (V1), freely moving, in vivo; two-photon voltage imaging of ASAP4e at 400 Hz over a 380 x 150 um FOV at 140-280 um depth (M-MINI2P))
Data and citation
- llms.txt — summary for language models
- llms-full.txt — every sensor in full (Markdown)
- gevis.json — all values and measurements with sources (JSON)
- gevis.csv — one row per sensor (CSV)
Cite GEVIBench as: Adam E. Cohen and Daozheng Gong (2026). Voltage imaging: A practical guide. Neuron. https://doi.org/10.1016/j.neuron.2026.08.002
Generated from the GEVIBench database on 2026-10-12.