GEVIBench › All sensors › FORCE1s
FORCE1s
Positive-going variant evolved from JEDI-2P with substantially larger spike responses, high intrinsic brightness, and repolarization kinetics tuned for 2P imaging.
- Category: VSD-cpGFP GEVI
- Published: 2026-04-10 — bioRxiv 2026
- Derived from: JEDI-2P
- Response polarity: positive-going (fluorescence increases on depolarization)
- Spectrum: excitation peak 489 nm, emission peak 516 nm (FORCE1s)
- Two-photon compatible: yes
- Tags: cpGFP, Green, Positive-going, Two-photon
Headline values (as shown in the GEVIBench table)
| Metric | Value | Definition |
|---|---|---|
| Brightness (B/B_EGFP) | 0.22× EGFP | Molecular brightness relative to EGFP (extinction coefficient × quantum yield, or a measured ratio). Sensors not measured against EGFP directly are placed through a chain of pairwise brightness comparisons, combined by geometric mean. |
| Kinetics τ_on / τ_off (ms) | 3.7 / 6.0 ms | Activation / decay time constants in ms (amplitude-weighted mean τ for multi-exponential fits). The value shown averages the measurements made at physiological temperature (≥33 °C); if there are none, it is the measurement closest to 33 °C. |
| ΔF/F per 100 mV | +267% | Steady-state fluorescence change for a 100 mV depolarization step (−70 → +30 mV); the sign gives the polarity. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting. |
| ΔF/F per mV | 1.2% | Subthreshold sensitivity: fluorescence change per mV near rest (−90 to −50 mV). Where no value is reported directly, it is estimated from the F–V curve. |
| ΔF/F per AP | 92.7% | Fluorescence change per single action potential in neurons. The table shows the first listed measurement; the median across measurements (one-photon preferred) is used for sorting. |
| AP width (FWHM, ms) | 3.8 ms | Full width at half maximum of the optical spike waveform. |
| Photostability t75% @ 100 mW/mm² | — | Time for fluorescence to fall to 75% of its initial value under one-photon illumination, linearly dose-scaled to 100 mW/mm² (t50% is used where the 75% crossing falls inside a fast initial transient). Two-photon curves are not dose-scaled and are excluded. |
| Papers using it (N_used) | 1 | Number of published research papers, tracked by GEVIBench, that used the sensor for an experiment (a popularity / track-record measure). |
Measurements and sources
Kinetics
- τ_on 3.72 ms, τ_off 5.95 ms at 33°C — McDonald 2026, Table S1.4
ΔF/F per 100 mV
- +267%, 2P — McDonald 2026, Fig. 1E
ΔF/F per mV (subthreshold)
- 1.2%/mV — McDonald 2026, Fig. 2F
ΔF/F per action potential
- 92.7%, 2P — McDonald 2026, Fig. 3B
AP width (FWHM)
- 2.6 ms at 7100 Hz sampling, Mouse, visual cortex L2/3, awake head-fixed, in vivo (ULoVE 2P), soma-targeted FORCE1s-Kv, 2P, 37°C — McDonald 2026, Fig. 3E
- 4.9 ms at 721 Hz sampling, HEK293A cells, whole-cell voltage clamp, in vitro (2-ms FWHM command AP waveform), 2P, 33°C — McDonald 2026, Fig. 1K
Brightness comparisons
- 0.39× the brightness of JEDI-2P — McDonald 2026, Fig. 1C
- 2× the brightness of ASAP4e — McDonald 2026, Fig. 1C
Photobleaching
- t75% = 65 s at 100 mW at sample plane (2P, 940 nm), 2P — McDonald 2026, Fig. S1.2B
Fluorescence–voltage (F–V) curve
ΔF/F (%) at each membrane potential, normalized to 0 at −70 mV: -120 mV: -46%; -100 mV: -34%; -80 mV: -13%; -70 mV: 0%; -60 mV: 21%; -40 mV: 88%; -20 mV: 169%; 0 mV: 227%; 20 mV: 252%; 30 mV: 267%; 50 mV: 282% — McDonald 2026, Fig. 1E
Research papers using FORCE1s (1)
- A versatile, positive-going voltage indicator that enables accessible two-photon recordings in vivo — McDonald AJ, Land MA, Yang S, et al., bioRxiv 2026 (Mouse, visual cortex L2/3, in vivo; Mouse, visual cortex, freely moving, in vivo; HEK293 cells, in vitro; Rat, hippocampal neurons, in vitro)
Data and citation
- llms.txt — summary for language models
- llms-full.txt — every sensor in full (Markdown)
- gevis.json — all values and measurements with sources (JSON)
- gevis.csv — one row per sensor (CSV)
Cite GEVIBench as: Adam E. Cohen and Daozheng Gong (2026). Voltage imaging: A practical guide. Neuron. https://doi.org/10.1016/j.neuron.2026.08.002
Generated from the GEVIBench database on 2026-10-12.